Categories: Analog multitesters
CX506a | Analog Multimeter with Capacitance Measurement and Built-in Transistor Oscillator
SPECIFICATIONS
Function
Measuring range
Tolerance
DCV
120m(4kΩ)/3/12/30/120 300(50kΩ/V)/1000V(15kΩ/V)
120m:±4% ±2.5% of full scale
ACV
3/12/30/120/300/750V(8kΩ/V)
±3% of full scale
(3/12V:±4% of full scale)
DCV
30?/0.3m/3m/30m/0.3A
±2.5% of full scale
(30V/0.3mA:±3% of full scale)
Resistance
5k/50k/500k/5M/50MΩ
Within ±3% of arc
Capacitance
C1:50p-0.2μF C2:0.01?-20μF
C3:1-2000 μF
C1/C2: ±6% of arc
C3: Approximate value
DC current gain hFE
Transistor hFE: 0 to 1000
Approximate value
Frequency characteristic
AC12V range or lower 40Hz to 30kHz, AC30V range 40Hz to 10 kHz: frequency response within ±3%
Battery
R6P(AA battery)1.5Vx2, 6F22(9V manganese battery)x1
Built-in fuse
F1176 Φ5x20mm 0.5A/250 V 1.5kA Ceramic fuse
Size/Mass
H165xW106xD46mm/Approx. 370g
€»The value in ()at DCV and ACV is input resistance
0 Reviews Write a review
Categories: Analog multitesters
YX361TR | Analog Multimeter - Variety of Measurement Functions using 24 Contact Switch
Specifications
Function
Range
Tolerance
DCV
0.1/0.5/2.5/10/50/250/1000V(20KΩ/V)
±2.5% of full scale
±DCV
±5/25V(40kΩ/V)
±5% of full scale
ACV
2.5/10/50/250/1000V(9kΩ/V)
±3% of full scale
(2.5/10V:±4% of full scale)
DCA
50μ/2.5m/25m/0.25A
±2.5% of full scale
Resistance
2k/20k/200k/2M/20MΩ
±3% of arc
Low-frequency output
-10~+62dB
±3% of full scale
(2.5/10V:±4% of full scale)
hFE
hFE: 0~1000
±3% of arc
Continuity
≦ approx.10Ω: LED lights. Open circuit voltage: approx. 3V
Battery check
1.5V
Bandwidth
40Hz~20kHz(Less than AC50V : ±3% of full scale)
Battery
R6P(AA battery)1.5Vx2, 6F22(9V manganese battery)x1
Fuse
F0301 Φ5x20mm 0.5A/250V 300A Glass fuse
Size/Mass
H150×W100×D37mm/Approx. 290g
*The value in ( )at DCV and ACV is input resistance
0 Reviews Write a review
Categories: Digital multimeters
CD772 | Digital Multimeter with Backlight & Temperature Measurement
Specifications
CD772
Measuring Range
Accuracy
Resolution
Input Impedance
DCV
400m/4/40/400/1000V
±(0.5%+2)
0.1mV
10M-100MΩ
ACV
4/40/400/1000V
±(1.2%+8)
0.001V
10M-11MΩ
DCA
400Ω/4000Ω/40m/400m/4/15A
±(1.4%+3)
0.1ΩA
ACA
400Ω/4000Ω/40m/400m/4/15A
±(1.8%+6)
0.1ΩA
Resistance
400/4k/40k/400k/4M/40M Ω
±(1.2%+5)
0.1Ω
Capacitance
50n/500n/5μ/50μ/100μF
±(5%+10)
0.01nF
Temperature
-20°C-300°C
±(3%+30)
0.1°C
Frequency
5/50/500/5k/50k/100kHz
±(0.3%+3)
0.001Hz
Continuity
Buzzer sounds and LED lights up at between 0Ω and 85Ω (±45 Ω )Open voltage: Approx. 0.4V
Diode test
Open voltage: approx.1.5V
Display
Numeral display 4000
Sampling rate
3 times/sec.
Bandwidth
45~500Hz(4V range)、45~1kHz(40V range and above)
Fuse
0.5A/1000V 30kA Φ6.35×32mm
16A/1000V 30kA Φ10×38mm
Battery
R6Px2
Battery life
Approx.150h (manganese battery) at DCV range
Size/Mass
H166×W82×D44mm/360g
Safety
IEC61010 CAT.Ⅲ 600V / CAT.Ⅱ 1000V
0 Reviews Write a review
Categories: Clamp meters
DCL3000R | True RMS AC Clamp Meter with Flexible Conductor
Specifications
Function
Range
Accuracy
Resolution
ACA
30/300/3000A
±(3.0%+5)
0.01A
Sampling rate
Approx. 2 times/sec.
Bandwidth
45-500Hz
Display
3150
Clamp diameter/Conductor size
Approx. Φ150mm max.
Max. overload protection input
AC5000A
Battery
LR03×2
Battery life
Approx. 130 hrs.
(Alkaline battery / Backlight off)
Size/Mass
H120×W70×D26mm (exc CT) / approx. 300g
Cable length
Approx. 1.8m
Safety standards
IEC61010 CAT.Ⅳ 600V
0 Reviews Write a review
Categories: Clamp meters
DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V
Specifications
Function
Range
Accuracy
Resolution
ACA
200.0/2000A
±(2.0%+5)
0.1A
DCA
200.0/2000A
±(2.0%+5)
0.1A
ACV
6.000/60.00/600.0/1000V
±(1.2%+5)
0.001V
DCV
6.000/60.00/600.0/1000V
±(0.5%+5)
0.001V
Resistance
600.0/6.000k/60.00k/600.0k/6.000M/40.00MΩ
±(0.5%+5)
0.1Ω
Frequency
10~1999Hz
±(0.1%+4)
0.01Hz
Capacitance
60n/600n/6μ/60μ/600μ/2000μF
±(2.0%+5)
0.01nF
Continuity
Buzzer sounds at below 10-200Ω Open voltage: approx. 0.5V
Diode test
Open voltage: approx. 1.8V
EF sensing
A voltage or electric field of about 60 V or more is detected. The barr graph and intermittent buzzer beeps change in three steps according to the field intensity. (50/60Hz)
Sampling rate
Approx. 5 times/sec.
Bandwidth
50~400Hz
Display
6000/1999(Hz)
Max. overload protection input
DC/AC1100V
CT: DC/AC2000A
Clamp diameter/Conductor size
Φ55mm/20x66mm
Battery
R6Px2
Battery life
A function: Approx. 80 hrs. Functions other than A: Approx. 240 hrs. (Zinc-carbon battery/Backlight off)
Size/Mass
H264×W97×D43mm/Approx. 640g
Safety standards
IEC61010 CAT Ⅳ 1000V
0 Reviews Write a review
Categories: Clamp meters
DCM600DR | Clamp Meter for Automotive Hybrid / Electric Vehicle + DMM Functionality
Specifications
Function
Range
Accuracy
Resolution
Input Impedance
DCA
60/600A
±(2%+5)
0.01A
ACA
60/600A
±(2%+5)
0.01A
DCV
600V
±(1%+2)
0.1V
1MΩ
ACV
600V
±(1.2%+5)
0.1V
Resistance
999.9Ω
±(1%+7)
0.1Ω
Continuity
Buzzer sounds at less than 40Ω
Open voltage: Approx. 2.9V
Sampling rate
3 times/sec.
Bandwidth
50-500Hz
Display
6000
Clamp diameter/Conductor size
Φ30mm/10×50mm
Battery
LR03×2
Battery life
Approx. 40 hrs. (Backlight off)
Size/Mass
H208×W69×D38mm
Approx. 260g
Safety standards
IEC61010 CAT.Ⅲ600V
*In the peak hold mode, the measuring range is fixed at 600A.
0 Reviews Write a review
Categories: Clamp meters
DCM660R | True RMS Clamp Meter for Electrical and HVAC Work + DMM Functions
Specifications
Function
Measuring Range
Accuracy
Resolution
Input Impedance
ACA
66/660A
±(2%+5)
0.01A
DCV
600V
±(1%+2)
0.1V
1MΩ
ACV
600V
±(1.2%+5)
0.1V
Frequency (A)
660/6.6k/30k
±(0.2%+1)
0.1Hz
Frequency (V)
660/6.6k/66k/100k
±(0.2%+1)
0.1Hz
Resistance
660Ω
±(1%+7)
0.1Ω
Continuity
Buzzer sounds at less than 30Ω Open voltage: approx. 1.2V
Sampling rate
3 times/sec.
Bandwidth
50-500Hz
Display
6600
Clamp diameter/Conductor size
Φ30mm/10×50mm
Battery
LR03×2
Battery life
Approx. 55 hrs.(Alkaline battery/Backlight off)
Size/Mass
H208×W69×D38mm/Approx. 265g
Safety standards
IEC61010 CAT.Ⅲ600V
0 Reviews Write a review
Categories: Clamp meters
DCL1000 | AC Clamp Meter Large Diameter CT 1000A
Function
Range
Accuracy
Resolution
ACA
400/1000A
±(1.7%+5)
0.1A
DCV
400m/4/40/400/600V
±(1.2%+3)
0.1mV
ACV
400m/4/40/400/600V
±(2.2%+5)
0.1mV
Resistance
400/4k/40k/400k/4M/40M Ω
±(1.2%+4)
0.1 Ω
Continuity
Buzzer sounds at between 0Ω and 65Ω (±35V)
Open voltage: approx. 0.4V
Diode test
Open voltage: approx. 1.6V
Sampling rate
3 times/sec.
Bandwidth
ACA 50/60Hz (sine wave)
ACV 50-500Hz (sine wave)
Display
4000
Clamp diameter/Conductor size
42mm/20x54mm
Battery
R03x2
Battery life
Approx. 120 hrs. at DCV (zinc-carbon battery)
Size/Mass
H238xW95xD45mm / Approx. 290g
Safety standards
IEC61010 CATIII 600V
0 Reviews Write a review
Categories: Clamp meters
DCM301 | AC Clamp Meter with Multimeter Functionality
Specifications
Function
Measuring Range
Accuracy
Resolution
ACA
60.00/600.0/1000A
±(2.5%+5)
0.01A
ACV
6.000/60.00/600.0/1000V
±(1.5%+3)
0.001V
DCV
6.000/60.00/600.0/1000V
±(1%+3)
0.001V
Resistance
6.000k/60.00k/600.0k/6.000M/60.00MΩ
±(2%+5)
0.001kΩ
Frequency
ACV 10Hz-10kHz, ACA 10Hz-2kHz
±(1%+5)
0.1Hz
Capacitance
60.00n/600.0n/6.000µ/60.00µ/600.0µ/6.000m/60.00mF
±(4%+3)
0.01nF
Continuity
Buzzer sounds below 30Ω Open voltage: approx. 1V or less
Detection of Electricity
Buzzer sounds, "-" is shown on LCD, and LED flickers
Detects ACV and EF of approx. 90V or more (50/60Hz)
Sampling rate
Approx. 3 times/sec.
Bandwidth
ACA 45-400Hz ACV 45Hz-1kHz
Display
6000/9999(Hz function)
Clamp diameter/Conductor size
Φ34mm/10×64mm
Battery
LR03×3
Battery life
Approx. 200 hrs.
Size/Mass
H252×W85×D40mm/Approx. 360g
Safety standards
IEC61010 CAT.Ⅳ600V/CAT.Ⅲ1000V
0 Reviews Write a review
Categories: Clamp meters
DCM400 | Basic Digital Clamp Meter with Multimeter Functionality
Specifications
Function
Range
Accuracy
Resistance
ACA
40/400A
±(1.9%+5)
0.01A
ACV
400/600V
±(1.5%+5)
0.1V
DCV
400/600V
±(1%+2)
0.1V
Resistance
400Ω
±(1%+2)
0.1Ω
Frequency (A)
20~4k/10kHz
±(0.1%+1)
1Hz
Frequency (V)
4k/40k/400k/1MHz
±(0.1%+1)
0.001kHz
Continuity
Buzzer sounds at less than approx. 40Ω
Open voltage: approx. 1.5V
Sampling rate
2 times/sec., 20 times/sec. for bar graph
Bandwidth
ACA 50/60Hz: ±(1.9%+5) 60-500Hz: ±(2.5%+5)
ACV 50-500Hz: ±(1.5%+5)
Display
4000
Clamp diameter/Conductor size
Φ25mm/10×34mm
Battery
R03×2
Battery life
Approx. 150 hrs. (Zinc-carbon battery)
Size/Mass
H193×W50×D28mm/Approx. 230g
Safety standards
IEC61010 CAT.Ⅲ300V CAT.Ⅱ600V
0 Reviews Write a review
Categories: Clamp meters
DCM400AD | Clamp Meter for Automotive Maintenance & Digital Multimeter Functions
SPECIFICATIONS
Function
Range
Accuracy
Resolution
ACA
40/400A
±(2%±10)
0.01A
DCA
40/400A
±(2.5%±10)
0.01A
ACV
400/600V
±(1.5%±5)
0.1V
DCV
400/600V
±(1%±2)
0.1V
Resistance
400Ω
±(1%±2)
0.1Ω
Continuity
Buzzer sounds at less than approx. 40Ω
Open voltage: approx. 1.5V
Sampling rate
2 times/sec., 20 times/sec. for bar graph
Bandwidth
50~500Hz
Display
4000
Clamp diameter/Conductor size
Φ25mm/10×34mm
Battery
LR03×2
Battery life
Approx. 50 hrs.(Alkaline battery)
Size/Mass
H193×W50×D28mm/Approx. 230g
Safety standards
IEC 61010 CAT.Ⅲ 300V CAT.Ⅱ 600V
0 Reviews Write a review
Categories: Clamp meters
DCM60R | Digital Clamp Meter / Multimeter
Specifications
Function
Range
Accuracy
Resistance
ACA
199.9/600A
±(2%+5)
0.1A
ACV
199.9/600V
±(1.5%+5)
0.1V
Resistance
199.9Ω
±(1.0%+8)
0.1Ω
Continuity
Buzzer sounds at less than 100Ω
Operation method
Δ-Σ method
AC measuring method
True RMS
Sampling rate
2 times / sec
Display
1999 count
Range selection
Auto
Battery low warning
Battery ( ) mark lights at approx. 2.2V or below
Operating temperature / humidity
0℃~40℃, below 80%RH No condensation
Storage temperature / humidity
-10℃~60℃, below 70%RH No condensation
Continuous use time
About 250 hours
Power consumption
Approx. 5.0mW
Safety standards
IEC61010-1, IEC61010-2-030 CAT.III 300V / II 600V
IEC61010-2-032, IEC61010-2-033, IEC61010-31
Bandwidth
50~400Hz
Clamp diameter / Conductor size
25mm / 10 x 30mm
Battery
R03(UM-4) or AAA x 2
Size / Mass
H187 x W50 x D29mm / 210g
Standard accessories included
Test leads (TL-21a), carrying case (C-DCM60L), instruction manual
0 Reviews Write a review
Categories: Insulation resistance testers
MG5000 | High Voltage Digital Insulation Tester
Specifications
Test Voltage(DC)
250V
500V
1000V
2500V
5000V
Range
0.0~104.9Ω
0.0~99.9MΩ
80~1049MΩ
0.0~99.9MΩ
80~999MΩ
0.80~2.09GΩ
0.0~99.9MΩ
80~999MΩ
0.80~9.99GΩ
8.0~104.9GΩ
0.0~99.9MΩ
80~999MΩ
0.80~9.99GΩ
8.0~99.9GΩ
80~1000GΩ
1001~1199GΩ
Accuracy
±5%+3
±5%+3
±5%+3
±5%+3
±5%+3
±20%
-
Open circuit voltage
DC250V
0%~+20%
DC500V
0%~+20%
DC1000V
0%~+20%
DC2500V
0%~+20%
DC5000V
0%~+20%
Rated current
3.0mA±0.5mA
Short-circuit current
3mA~4mA
Voltage measurement
AC:30~1000V(50/60Hz), DC:30~1000V, Accuracy:±(2%+3dgt)
Battery monitor
4-step indication
IP rate
IP54
Battery
LR14(C alkaline battery)1.5V×8
Size/Mass
H188×W225×D97mm/Approx. 1750g
Safety standard
IEC61010 CAT.IV 600V
0 Reviews Write a review
Categories: Insulation resistance testers
MG1000 | Digital Insulation Tester Dustproof + Splashproof IP54 Design
Specifications
Function
Measuring Range
Accuracy
Resolution
MΩ
4M/40M/400M/4000MΩ
±(3%+4)
0.001MΩ
Rated voltage
250/500/1000V
ACV/DCV
600V(AC/DC Automatic detection)
±(3%+2)
1V
Ω(Continuity)
4000Ω(Buzzer and ALARM indicator)
±(3%+3)
1Ω
Ω
40Ω
±(3%+10)
0.01Ω
Rated current
1.0~1.2mA
Short-circuit current
2mA or less
Live circuit detection
At 30V AC/DC or more, inhibits test, buzzer sounds and ALARM indicator lights up
Battery
LR6(AA alkaline battery)1.5V×6
Size/Mass
H170×W142×D57mm/Approx. 600g
Safety standard
IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review
Categories: Insulation resistance testers
PDM1529S | 1000V / 500V / 250V Analog Insulation Tester / Portable Insulation Resistance Meter
Specifications
Scale(MΩ)
0.5~2~1000~2000MΩ 1000V
0.02~0.1~50~100MΩ 500V/250V
Tolerance
± 5% of reading(1st effective measurement range:written in thick print above)
±10% of reading(2nd effective measurement range:written in small type above)
ACV
600V
Tolerance
Within ±5% of the max. scale value(50~60Hz sine wave)
DCV
60V
Tolerance
Within ±5% of the max. scale value
Rated current
1.0~1.2mA
Battery
6LF22/6LR61 (9V alkaline battery) x1
Size/Mass
H144×W99×D43mm / Appox. 310g
Safety standard
IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review
Categories: Insulation resistance testers
DM1009S | 1000V Analog Insulation Tester / Portable Insulation Resistance Meter
Specifications
Scale(MΩ)
1~2~1000~2000MΩ
Tolerance
± 5% of reading(1st effective measurement range: written in the thick print above)
±10% of reading(2nd effective measurement range: written in small type above)
ACV
600V
Tolerance
Within ±5% of the max. scale value(50~60Hz sine wave)
DCV
60V
Tolerance
Within ±5% of the max. scale value
Rated current
1.0~1.2mA
Battery
6LF22/6LR61 (9V alkaline battery) x1
Size/Mass
H144×W99×D43mm / Approx. 310g
Safety standard
IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review
Categories: Insulation resistance testers
DM509S | 500V Analog Insulation Tester / Portable Insulation Resistance Meter
Specifications
Measuring Range
Accuracy
MΩ (Insulation Resistance)
500V/1000MΩ
1st effective measurement range: ±5% of full scale 2nd effective measurement range: ±10% of a full scale
DCV
60V
±5% of full scale
ACV
600V
±5% of full scale
Rated measuring current
1~1.2mA
Meter type
Internal magnet, Taut-band meter(24μA)
AC rectifier form
Half-wave rectification (Mean value indication rms value converted)
Operating temperature / humidity
0℃~43℃ 80%RH or below No condensation
Storage temperature / humidity
-10℃~50℃ 70%RH or below No condensation
Operating environment
Altitude 2000m or less, environmental pollution degree II
Power consumption
Approx. 2.0W~2.8W(At 500V/100MΩ range)
Battery consumption
Checked by BATTERY CHECK range
IP rate
IP20
EN61010-1 CAT.II EN61010-1 CAT.III
1000V 600V
Battery
6LR61 (9V) x 1
Size / Mass
H144 x W99 x D43mm / 310g
Standard accessories included
Test lead (TL-509S), Carrying case (C-09S), Instruction manual
0 Reviews Write a review
Categories: Detectors
KS1 | 3 Phase Detector - Contact Type
Specifications
Measurement
Open Phase and Phase Rotation Detection
Voltage range
3 Phase AC100 to 500 V
Frequency
45 to 70 Hz
Time limit
AC110V: Continuous
AC220V: 3 hours
AC480V: 12 minutes
Safey standards
IEC61010-1 CATⅢ 500V
IEC61326、IEC61010-031
Size/Mass
102(H)×78(W)×32.5(D)mm / approx. 212 grams
Cord length
Approx. 0.6 m
Accessories
Carrying pouch, instruction manual x 1
0 Reviews Write a review