Showing 1–20 of 34 results

Sort by
Show
Filter

CX506a | Analog Multimeter with Capacitance Measurement and Built-in Transistor Oscillator

SPECIFICATIONS
Function Measuring range Tolerance DCV 120m(4kΩ)/3/12/30/120 300(50kΩ/V)/1000V(15kΩ/V) 120m:±4% ±2.5% of full scale ACV 3/12/30/120/300/750V(8kΩ/V) ±3% of full scale (3/12V:±4% of full scale) DCV 30?/0.3m/3m/30m/0.3A ±2.5% of full scale (30V/0.3mA:±3% of full scale) Resistance 5k/50k/500k/5M/50MΩ Within ±3% of arc Capacitance C1:50p-0.2μF C2:0.01?-20μF C3:1-2000 μF C1/C2: ±6% of arc C3: Approximate value DC current gain hFE Transistor hFE: 0 to 1000 Approximate value
Frequency characteristic AC12V range or lower 40Hz to 30kHz, AC30V range 40Hz to 10 kHz: frequency response within ±3% Battery R6P(AA battery)1.5Vx2, 6F22(9V manganese battery)x1 Built-in fuse F1176 Φ5x20mm 0.5A/250 V 1.5kA Ceramic fuse Size/Mass H165xW106xD46mm/Approx. 370g €»The value in ()at DCV and ACV is input resistance
0 Reviews Write a review

YX361TR | Analog Multimeter - Variety of Measurement Functions using 24 Contact Switch

Specifications
Function Range Tolerance DCV 0.1/0.5/2.5/10/50/250/1000V(20KΩ/V) ±2.5% of full scale ±DCV ±5/25V(40kΩ/V) ±5% of full scale ACV 2.5/10/50/250/1000V(9kΩ/V) ±3% of full scale (2.5/10V:±4% of full scale) DCA 50μ/2.5m/25m/0.25A ±2.5% of full scale Resistance 2k/20k/200k/2M/20MΩ ±3% of arc Low-frequency output -10~+62dB ±3% of full scale (2.5/10V:±4% of full scale) hFE hFE: 0~1000 ±3% of arc Continuity ≦ approx.10Ω: LED lights. Open circuit voltage: approx. 3V Battery check 1.5V
Bandwidth 40Hz~20kHz(Less than AC50V : ±3% of full scale) Battery R6P(AA battery)1.5Vx2, 6F22(9V manganese battery)x1 Fuse F0301 Φ5x20mm 0.5A/250V 300A Glass fuse Size/Mass H150×W100×D37mm/Approx. 290g *The value in ( )at DCV and ACV is input resistance
0 Reviews Write a review

CD772 | Digital Multimeter with Backlight & Temperature Measurement

Specifications
CD772 Measuring Range Accuracy Resolution Input Impedance DCV 400m/4/40/400/1000V ±(0.5%+2) 0.1mV 10M-100MΩ ACV 4/40/400/1000V ±(1.2%+8) 0.001V 10M-11MΩ DCA 400Ω/4000Ω/40m/400m/4/15A ±(1.4%+3) 0.1ΩA   ACA 400Ω/4000Ω/40m/400m/4/15A ±(1.8%+6) 0.1ΩA Resistance 400/4k/40k/400k/4M/40M Ω ±(1.2%+5) 0.1Ω Capacitance 50n/500n/5μ/50μ/100μF ±(5%+10) 0.01nF Temperature -20°C-300°C ±(3%+30) 0.1°C Frequency 5/50/500/5k/50k/100kHz ±(0.3%+3) 0.001Hz Continuity Buzzer sounds and LED lights up at between 0Ω  and 85Ω (±45 Ω )Open voltage: Approx. 0.4V Diode test Open voltage: approx.1.5V
Display Numeral display 4000 Sampling rate 3 times/sec. Bandwidth 45~500Hz(4V range)、45~1kHz(40V range and above) Fuse 0.5A/1000V 30kA Φ6.35×32mm 16A/1000V 30kA Φ10×38mm Battery R6Px2 Battery life Approx.150h (manganese battery) at DCV range Size/Mass H166×W82×D44mm/360g Safety IEC61010 CAT.Ⅲ 600V / CAT.Ⅱ 1000V
0 Reviews Write a review
Categories:

DCL3000R | True RMS AC Clamp Meter with Flexible Conductor

Specifications
Function Range Accuracy Resolution ACA 30/300/3000A ±(3.0%+5) 0.01A
Sampling rate Approx. 2 times/sec. Bandwidth 45-500Hz Display 3150 Clamp diameter/Conductor size Approx. Φ150mm max. Max. overload protection input AC5000A Battery LR03×2 Battery life Approx. 130 hrs. (Alkaline battery / Backlight off) Size/Mass H120×W70×D26mm (exc CT) / approx. 300g Cable length Approx. 1.8m Safety standards IEC61010 CAT.Ⅳ 600V
0 Reviews Write a review
Categories:

DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V

Specifications
Function Range Accuracy Resolution ACA 200.0/2000A ±(2.0%+5) 0.1A DCA 200.0/2000A ±(2.0%+5) 0.1A ACV 6.000/60.00/600.0/1000V ±(1.2%+5) 0.001V DCV 6.000/60.00/600.0/1000V ±(0.5%+5) 0.001V Resistance 600.0/6.000k/60.00k/600.0k/6.000M/40.00MΩ ±(0.5%+5) 0.1Ω Frequency 10~1999Hz ±(0.1%+4) 0.01Hz Capacitance 60n/600n/6μ/60μ/600μ/2000μF ±(2.0%+5) 0.01nF Continuity Buzzer sounds at below 10-200Ω Open voltage: approx. 0.5V Diode test Open voltage: approx. 1.8V EF sensing A voltage or electric field of about 60 V or more is detected. The barr graph and intermittent buzzer beeps change in three steps according to the field intensity. (50/60Hz)
Sampling rate Approx. 5 times/sec. Bandwidth 50~400Hz Display 6000/1999(Hz) Max. overload protection input DC/AC1100V CT: DC/AC2000A Clamp diameter/Conductor size Φ55mm/20x66mm Battery R6Px2 Battery life A function: Approx. 80 hrs. Functions other than A: Approx. 240 hrs. (Zinc-carbon battery/Backlight off) Size/Mass H264×W97×D43mm/Approx. 640g Safety standards IEC61010 CAT Ⅳ 1000V
0 Reviews Write a review
Categories:

DCM600DR | Clamp Meter for Automotive Hybrid / Electric Vehicle + DMM Functionality

Specifications
Function Range Accuracy Resolution Input Impedance DCA 60/600A ±(2%+5) 0.01A ACA 60/600A ±(2%+5) 0.01A DCV 600V ±(1%+2) 0.1V 1MΩ ACV 600V ±(1.2%+5) 0.1V Resistance 999.9Ω ±(1%+7) 0.1Ω Continuity Buzzer sounds at less than 40Ω Open voltage: Approx. 2.9V
Sampling rate 3 times/sec. Bandwidth 50-500Hz Display 6000 Clamp diameter/Conductor size Φ30mm/10×50mm Battery LR03×2 Battery life Approx. 40 hrs. (Backlight off) Size/Mass H208×W69×D38mm Approx. 260g Safety standards IEC61010 CAT.Ⅲ600V *In the peak hold mode, the measuring range is fixed at 600A.
0 Reviews Write a review
Categories:

DCM660R | True RMS Clamp Meter for Electrical and HVAC Work + DMM Functions

Specifications
Function Measuring Range Accuracy Resolution Input Impedance ACA 66/660A ±(2%+5) 0.01A DCV 600V ±(1%+2) 0.1V 1MΩ ACV 600V ±(1.2%+5) 0.1V Frequency (A) 660/6.6k/30k ±(0.2%+1) 0.1Hz Frequency (V) 660/6.6k/66k/100k ±(0.2%+1) 0.1Hz Resistance 660Ω ±(1%+7) 0.1Ω Continuity Buzzer sounds at less than 30Ω Open voltage: approx. 1.2V
Sampling rate 3 times/sec. Bandwidth 50-500Hz Display 6600 Clamp diameter/Conductor size Φ30mm/10×50mm Battery LR03×2 Battery life Approx. 55 hrs.(Alkaline battery/Backlight off) Size/Mass H208×W69×D38mm/Approx. 265g Safety standards IEC61010 CAT.Ⅲ600V
0 Reviews Write a review
Categories:

DCL1000 | AC Clamp Meter Large Diameter CT 1000A

Function Range Accuracy Resolution ACA 400/1000A ±(1.7%+5) 0.1A DCV 400m/4/40/400/600V ±(1.2%+3) 0.1mV ACV 400m/4/40/400/600V ±(2.2%+5) 0.1mV Resistance 400/4k/40k/400k/4M/40M Ω ±(1.2%+4) 0.1 Ω Continuity Buzzer sounds at between 0Ω and 65Ω (±35V) Open voltage: approx. 0.4V Diode test Open voltage: approx. 1.6V
Sampling rate 3 times/sec. Bandwidth ACA 50/60Hz (sine wave) ACV 50-500Hz (sine wave) Display 4000 Clamp diameter/Conductor size 42mm/20x54mm Battery R03x2 Battery life Approx. 120 hrs. at DCV (zinc-carbon battery) Size/Mass H238xW95xD45mm / Approx. 290g Safety standards IEC61010 CATIII 600V
0 Reviews Write a review
Categories:

DCM301 | AC Clamp Meter with Multimeter Functionality

Specifications  
Function Measuring Range Accuracy Resolution ACA 60.00/600.0/1000A ±(2.5%+5) 0.01A ACV 6.000/60.00/600.0/1000V ±(1.5%+3) 0.001V DCV 6.000/60.00/600.0/1000V ±(1%+3) 0.001V Resistance 6.000k/60.00k/600.0k/6.000M/60.00MΩ ±(2%+5) 0.001kΩ Frequency ACV 10Hz-10kHz, ACA 10Hz-2kHz ±(1%+5) 0.1Hz Capacitance 60.00n/600.0n/6.000µ/60.00µ/600.0µ/6.000m/60.00mF ±(4%+3) 0.01nF Continuity Buzzer sounds below 30Ω Open voltage: approx. 1V or less Detection of Electricity Buzzer sounds, "-" is shown on LCD, and LED flickers Detects ACV and EF of approx. 90V or more (50/60Hz)
Sampling rate Approx. 3 times/sec. Bandwidth ACA 45-400Hz ACV 45Hz-1kHz Display 6000/9999(Hz function) Clamp diameter/Conductor size Φ34mm/10×64mm Battery LR03×3 Battery life Approx. 200 hrs. Size/Mass H252×W85×D40mm/Approx. 360g Safety standards IEC61010 CAT.Ⅳ600V/CAT.Ⅲ1000V
0 Reviews Write a review
Categories:

DCM400 | Basic Digital Clamp Meter with Multimeter Functionality

Specifications
Function Range Accuracy Resistance ACA 40/400A ±(1.9%+5) 0.01A ACV 400/600V ±(1.5%+5) 0.1V DCV 400/600V ±(1%+2) 0.1V Resistance 400Ω ±(1%+2) 0.1Ω Frequency (A) 20~4k/10kHz ±(0.1%+1) 1Hz Frequency (V) 4k/40k/400k/1MHz ±(0.1%+1) 0.001kHz Continuity Buzzer sounds at less than approx. 40Ω Open voltage: approx. 1.5V
Sampling rate 2 times/sec., 20 times/sec. for bar graph Bandwidth ACA 50/60Hz: ±(1.9%+5) 60-500Hz: ±(2.5%+5) ACV 50-500Hz: ±(1.5%+5) Display 4000 Clamp diameter/Conductor size Φ25mm/10×34mm Battery R03×2 Battery life Approx. 150 hrs. (Zinc-carbon battery) Size/Mass H193×W50×D28mm/Approx. 230g Safety standards IEC61010 CAT.Ⅲ300V CAT.Ⅱ600V
0 Reviews Write a review
Categories:

DCM400AD | Clamp Meter for Automotive Maintenance & Digital Multimeter Functions

SPECIFICATIONS  
Function Range Accuracy Resolution ACA 40/400A ±(2%±10) 0.01A DCA 40/400A ±(2.5%±10) 0.01A ACV 400/600V ±(1.5%±5) 0.1V DCV 400/600V ±(1%±2) 0.1V Resistance 400Ω ±(1%±2) 0.1Ω Continuity Buzzer sounds at less than approx. 40Ω Open voltage: approx. 1.5V
Sampling rate 2 times/sec., 20 times/sec. for bar graph Bandwidth 50~500Hz Display 4000 Clamp diameter/Conductor size Φ25mm/10×34mm Battery LR03×2 Battery life Approx. 50 hrs.(Alkaline battery) Size/Mass H193×W50×D28mm/Approx. 230g Safety standards IEC 61010 CAT.Ⅲ 300V CAT.Ⅱ 600V
0 Reviews Write a review
Categories:

DCM60R | Digital Clamp Meter / Multimeter

Specifications
Function Range Accuracy Resistance ACA 199.9/600A ±(2%+5) 0.1A ACV 199.9/600V ±(1.5%+5) 0.1V Resistance 199.9Ω ±(1.0%+8) 0.1Ω Continuity Buzzer sounds at less than 100Ω
Operation method Δ-Σ method AC measuring method True RMS Sampling rate 2 times / sec Display 1999 count Range selection Auto Battery low warning Battery ( ) mark lights at approx. 2.2V or below Operating temperature / humidity 0℃~40℃, below 80%RH No condensation Storage temperature / humidity -10℃~60℃, below 70%RH No condensation Continuous use time About 250 hours Power consumption Approx. 5.0mW Safety standards IEC61010-1, IEC61010-2-030 CAT.III 300V / II 600V IEC61010-2-032, IEC61010-2-033, IEC61010-31 Bandwidth 50~400Hz Clamp diameter / Conductor size 25mm / 10 x 30mm Battery R03(UM-4) or AAA x 2 Size / Mass H187 x W50 x D29mm / 210g Standard accessories included Test leads (TL-21a), carrying case (C-DCM60L), instruction manual
0 Reviews Write a review

MG5000 | High Voltage Digital Insulation Tester

Specifications
Test Voltage(DC) 250V 500V 1000V 2500V 5000V Range 0.0~104.9Ω 0.0~99.9MΩ 80~1049MΩ 0.0~99.9MΩ 80~999MΩ 0.80~2.09GΩ 0.0~99.9MΩ 80~999MΩ 0.80~9.99GΩ 8.0~104.9GΩ 0.0~99.9MΩ 80~999MΩ 0.80~9.99GΩ 8.0~99.9GΩ 80~1000GΩ 1001~1199GΩ Accuracy ±5%+3 ±5%+3 ±5%+3 ±5%+3 ±5%+3 ±20% - Open circuit voltage DC250V 0%~+20% DC500V 0%~+20% DC1000V 0%~+20% DC2500V 0%~+20% DC5000V 0%~+20%
Rated current 3.0mA±0.5mA Short-circuit current 3mA~4mA Voltage measurement AC:30~1000V(50/60Hz), DC:30~1000V, Accuracy:±(2%+3dgt) Battery monitor 4-step indication IP rate IP54 Battery LR14(C alkaline battery)1.5V×8 Size/Mass H188×W225×D97mm/Approx. 1750g Safety standard IEC61010 CAT.IV 600V
0 Reviews Write a review

MG1000 | Digital Insulation Tester Dustproof + Splashproof IP54 Design

Specifications
Function Measuring Range Accuracy Resolution MΩ 4M/40M/400M/4000MΩ ±(3%+4) 0.001MΩ Rated voltage 250/500/1000V ACV/DCV 600V(AC/DC Automatic detection) ±(3%+2) 1V Ω(Continuity) 4000Ω(Buzzer and ALARM indicator) ±(3%+3) 1Ω Ω 40Ω ±(3%+10) 0.01Ω
Rated current 1.0~1.2mA Short-circuit current 2mA or less Live circuit detection At 30V AC/DC or more, inhibits test, buzzer sounds and ALARM indicator lights up Battery LR6(AA alkaline battery)1.5V×6 Size/Mass H170×W142×D57mm/Approx. 600g Safety standard IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review

PDM1529S | 1000V / 500V / 250V Analog Insulation Tester / Portable Insulation Resistance Meter

Specifications
Scale(MΩ) 0.5~2~1000~2000MΩ 1000V 0.02~0.1~50~100MΩ 500V/250V Tolerance ± 5% of reading(1st effective measurement range:written in thick print above) ±10% of reading(2nd effective measurement range:written in small type above) ACV 600V Tolerance Within ±5% of the max. scale value(50~60Hz sine wave) DCV 60V Tolerance Within ±5% of the max. scale value Rated current 1.0~1.2mA Battery 6LF22/6LR61 (9V alkaline battery) x1 Size/Mass H144×W99×D43mm / Appox. 310g Safety standard IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review

DM1009S | 1000V Analog Insulation Tester / Portable Insulation Resistance Meter

Specifications
Scale(MΩ) 1~2~1000~2000MΩ Tolerance ± 5% of reading(1st effective measurement range: written in the thick print above) ±10% of reading(2nd effective measurement range: written in small type above) ACV 600V Tolerance Within ±5% of the max. scale value(50~60Hz sine wave) DCV 60V Tolerance Within ±5% of the max. scale value Rated current 1.0~1.2mA Battery 6LF22/6LR61 (9V alkaline battery) x1 Size/Mass H144×W99×D43mm / Approx. 310g Safety standard IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review

DM509S | 500V Analog Insulation Tester / Portable Insulation Resistance Meter

Specifications
Measuring Range Accuracy MΩ (Insulation Resistance) 500V/1000MΩ 1st effective measurement range: ±5% of full scale 2nd effective measurement range: ±10% of a full scale DCV 60V ±5% of full scale ACV 600V ±5% of full scale Rated measuring current 1~1.2mA Meter type Internal magnet, Taut-band meter(24μA) AC rectifier form Half-wave rectification (Mean value indication rms value converted) Operating temperature / humidity 0℃~43℃ 80%RH or below No condensation Storage temperature / humidity -10℃~50℃ 70%RH or below No condensation Operating environment Altitude 2000m or less, environmental pollution degree II Power consumption Approx. 2.0W~2.8W(At 500V/100MΩ range) Battery consumption Checked by BATTERY CHECK range IP rate IP20 EN61010-1 CAT.II EN61010-1 CAT.III 1000V 600V Battery 6LR61 (9V) x 1 Size / Mass H144 x W99 x D43mm / 310g Standard accessories included Test lead (TL-509S), Carrying case (C-09S), Instruction manual
0 Reviews Write a review
Categories:

KS1 | 3 Phase Detector - Contact Type

Specifications
Measurement Open Phase and Phase Rotation Detection Voltage range 3 Phase AC100 to 500 V Frequency 45 to 70 Hz Time limit AC110V: Continuous AC220V: 3 hours AC480V: 12 minutes Safey standards IEC61010-1 CATⅢ 500V IEC61326、IEC61010-031 Size/Mass 102(H)×78(W)×32.5(D)mm / approx. 212 grams Cord length Approx. 0.6 m Accessories Carrying pouch, instruction manual x 1
0 Reviews Write a review