AP33 | Analog Pocket Multimeter
Specifications
Range
Accuracy
DCV
10/50/250/500V (2kΩ/V)
±5% of full scale
ACV
50/250/500V (2kΩ/V)
±5% of full scale
Battery Check
1.5V/9V
-
DCA
25m/250mA
±5% of full scale
Resistance
5k/500kΩ
±3% arc
Meter Type
Pivot Meter
Operating temperature / humidity
5℃~40℃ 80%RH or below / No condensation
Storage temperature / humidity
-10℃~50℃ 70%RH or below / No condensation
Operating environment
Altitude 2000m or less, indoor use, environmental pollution degree II
Bandwidth
40~10kHz (less than 50V)
Fuse
0.5A/250V Φ5.0x20mm
Battery
R03 x 1
Size / Weight
126H x 87W x 30D mm / 185g
Standard accessories included
Instruction manual
0 Reviews Write a review
Categories: Digital multimeters
CD732 | Digital Multimeter with High-Speed Bar Graph & Continuity Buzzer with LED
Specifications
CD732
Measuring Range
Accuracy
Resolution
Input impedance
DCV
600m/6/60/600/1000V
±(0.5%+2)
0.1mV
10M-100M
Ω
ACV 6/60/600/750V ±(1.2%+5) 0.001V 10M-11MΩ
DCA 600 μ/6000 μ/60m/600m/6/15A ±(1.5%+3) 0.1μA ACA 600 μ/6000 μ/60m/600m/6/15A ±(1.8%+5) 0.1μA Resistance 600/6k/60k/600k/6M/60M ±(1.2%+4) 0.1 μ Capacitance 40n/400n/4μ/40μ/400μ/4000μ ±(5.0%+6) 0.01nF Frequency 9.999/99.99/999.9/9.999k/99.99k ±(0.5%+3) 0.001Hz Duty cycle 20-80% +0.5%+5) Continuity Buzzer sounds and LED lights up at between 10-60V Open voltage: approx. 0.63V Diode test Open voltage: approx. 2.7V
Display
Numeric display: 6000
Bar graph: 61 segments
Sampling rate
3 times/sec., 30 times/sec. for bar graph
Bandwidth
45-500Hz
Fuse
0.4A/1000V 30kA φ6.3x32mm
16A/1000V 30kA φ10x38mm
Battery
R6 (1.5V)x2
Battery life
Approx. 400h (manganese battery) at DCV range
Size/Mass
H167xW90xD48mm / 320g (including holster)
Safety standard
IEC61010 CATIII 600V /CATII 1000V
0 Reviews Write a review
Categories: Digital multimeters
CD771 | Digital Multimeter with Backlight & Continuity Buzzer with LED
CD771
Measuring Range
Accuracy
Resolution
Input Impedance
DCV
400m/4/40/400/1000V
±(0.5%+2)
0.1mV
10M-100MΩ
ACV
4/40/400/1000V
±(1.2%+7)
0.001V
10M-11MΩ
DCA
400Ω/4000Ω/40m/400m/4/10A
±(1.4%+3)
0.1ΩA
ACA
400Ω/4000Ω/40m/400m/4/10A
±(1.8%+5)
0.1ΩA
Resistance
400/4k/40k/400k/4M/40MΩ
±(1.2%+5)
0.1Ω
Capacitance
50Ω500n/5Ω/50Ω/100ΩF
±(5%+10)
0.01nF
Frequency
5/50/500/5k/50k/100kHz
±(0.3%+3)
0.001Hz
Continuity
Buzzer sounds and LED lights up at between 0Ω and 85Ω(±45Ω). Open voltage:Approx.0.4V
Diode test
Open voltage:approx.1.5V
Battery Check
Approximate value(30Ω load)1.5V battery only
Display
Numeral display 4000
Sampling rate
3 times/sec.
Bandwidth
40-400Hz(Sine wave)
Fuse
0.5A/1000V 30kA Ω6.35x32mm 10A/1000V 30kA Ω10x38mm
Battery
R6Px2
Battery life
Approx.400h (manganese battery) at DCV range
Size/Mass
H166xW82xD44mm/360g
Safety
IEC61010CATIII600V/CATII1000V
0 Reviews Write a review
Categories: Digital multimeters
CD772 | Digital Multimeter with Backlight & Temperature Measurement
Specifications
CD772
Measuring Range
Accuracy
Resolution
Input Impedance
DCV
400m/4/40/400/1000V
±(0.5%+2)
0.1mV
10M-100MΩ
ACV
4/40/400/1000V
±(1.2%+8)
0.001V
10M-11MΩ
DCA
400Ω/4000Ω/40m/400m/4/15A
±(1.4%+3)
0.1ΩA
ACA
400Ω/4000Ω/40m/400m/4/15A
±(1.8%+6)
0.1ΩA
Resistance
400/4k/40k/400k/4M/40M Ω
±(1.2%+5)
0.1Ω
Capacitance
50n/500n/5μ/50μ/100μF
±(5%+10)
0.01nF
Temperature
-20°C-300°C
±(3%+30)
0.1°C
Frequency
5/50/500/5k/50k/100kHz
±(0.3%+3)
0.001Hz
Continuity
Buzzer sounds and LED lights up at between 0Ω and 85Ω (±45 Ω )Open voltage: Approx. 0.4V
Diode test
Open voltage: approx.1.5V
Display
Numeral display 4000
Sampling rate
3 times/sec.
Bandwidth
45~500Hz(4V range)、45~1kHz(40V range and above)
Fuse
0.5A/1000V 30kA Φ6.35×32mm
16A/1000V 30kA Φ10×38mm
Battery
R6Px2
Battery life
Approx.150h (manganese battery) at DCV range
Size/Mass
H166×W82×D44mm/360g
Safety
IEC61010 CAT.Ⅲ 600V / CAT.Ⅱ 1000V
0 Reviews Write a review
Categories: Digital multimeters
CD800a | Digital Multimeter with Tough Body Cover
CD800a
Measuring Range
Accuracy
Resolution
Input Impedance
DCV
400m/4/40/400/600V
±(0.7%+3)
0.1mV
10M-100M Ω
ACV
4/40/400/600V
±(1.6%+5)
0.001V
10M-11M Ω
DCA
40m/400mA
±(2.2%+5)
0.01mA
ACA
40m/400mA
±(2.8%+5)
0.01mA
Resistance
400/4k/40k/400k/4M/40M Ω
±(1.2%+5)
0.1 Ω
Capacitance
50n/500n/5 μ/50 μ/100 μF
±(5%+10)
0.01nF
Frequency
5Hz-100kHz
+0.5%+3)
Duty cycle
20%-80%
+0.5%+5)
Continuity
Buzzer sounds at between 10 Ω and 120 Ω Open voltage: Approx.0.4V
Diode test
Open voltage: Approx.1.5V
Display
numeral display 4000
Sampling rate
3 times/sec.
Bandwidth
40Hz-400Hz
Fuse
0.5A/250V 1.5kA Φ5x20 Ceramic
Battery
R6P(1.5V)x2
Battery life
Approx.500h (manganese battery) at DCV range
Size/Mass
H176xW104xD46mm/Approx.340g
Test lead length/Pin tip
Length: approx. 0.7m/19mm
0 Reviews Write a review
Categories: Analog multitesters
CX506a | Analog Multimeter with Capacitance Measurement and Built-in Transistor Oscillator
SPECIFICATIONS
Function
Measuring range
Tolerance
DCV
120m(4kΩ)/3/12/30/120 300(50kΩ/V)/1000V(15kΩ/V)
120m:±4% ±2.5% of full scale
ACV
3/12/30/120/300/750V(8kΩ/V)
±3% of full scale
(3/12V:±4% of full scale)
DCV
30?/0.3m/3m/30m/0.3A
±2.5% of full scale
(30V/0.3mA:±3% of full scale)
Resistance
5k/50k/500k/5M/50MΩ
Within ±3% of arc
Capacitance
C1:50p-0.2μF C2:0.01?-20μF
C3:1-2000 μF
C1/C2: ±6% of arc
C3: Approximate value
DC current gain hFE
Transistor hFE: 0 to 1000
Approximate value
Frequency characteristic
AC12V range or lower 40Hz to 30kHz, AC30V range 40Hz to 10 kHz: frequency response within ±3%
Battery
R6P(AA battery)1.5Vx2, 6F22(9V manganese battery)x1
Built-in fuse
F1176 Φ5x20mm 0.5A/250 V 1.5kA Ceramic fuse
Size/Mass
H165xW106xD46mm/Approx. 370g
€»The value in ()at DCV and ACV is input resistance
0 Reviews Write a review
Categories: Clamp meters
DCL1000 | AC Clamp Meter Large Diameter CT 1000A
Function
Range
Accuracy
Resolution
ACA
400/1000A
±(1.7%+5)
0.1A
DCV
400m/4/40/400/600V
±(1.2%+3)
0.1mV
ACV
400m/4/40/400/600V
±(2.2%+5)
0.1mV
Resistance
400/4k/40k/400k/4M/40M Ω
±(1.2%+4)
0.1 Ω
Continuity
Buzzer sounds at between 0Ω and 65Ω (±35V)
Open voltage: approx. 0.4V
Diode test
Open voltage: approx. 1.6V
Sampling rate
3 times/sec.
Bandwidth
ACA 50/60Hz (sine wave)
ACV 50-500Hz (sine wave)
Display
4000
Clamp diameter/Conductor size
42mm/20x54mm
Battery
R03x2
Battery life
Approx. 120 hrs. at DCV (zinc-carbon battery)
Size/Mass
H238xW95xD45mm / Approx. 290g
Safety standards
IEC61010 CATIII 600V
0 Reviews Write a review
Categories: Clamp meters
DCL3000R | True RMS AC Clamp Meter with Flexible Conductor
Specifications
Function
Range
Accuracy
Resolution
ACA
30/300/3000A
±(3.0%+5)
0.01A
Sampling rate
Approx. 2 times/sec.
Bandwidth
45-500Hz
Display
3150
Clamp diameter/Conductor size
Approx. Φ150mm max.
Max. overload protection input
AC5000A
Battery
LR03×2
Battery life
Approx. 130 hrs.
(Alkaline battery / Backlight off)
Size/Mass
H120×W70×D26mm (exc CT) / approx. 300g
Cable length
Approx. 1.8m
Safety standards
IEC61010 CAT.Ⅳ 600V
0 Reviews Write a review
Categories: Clamp meters
DCM2000DR | Clamp Meter AC/DC Max Current 2000A - CAT IV 1000V
Specifications
Function
Range
Accuracy
Resolution
ACA
200.0/2000A
±(2.0%+5)
0.1A
DCA
200.0/2000A
±(2.0%+5)
0.1A
ACV
6.000/60.00/600.0/1000V
±(1.2%+5)
0.001V
DCV
6.000/60.00/600.0/1000V
±(0.5%+5)
0.001V
Resistance
600.0/6.000k/60.00k/600.0k/6.000M/40.00MΩ
±(0.5%+5)
0.1Ω
Frequency
10~1999Hz
±(0.1%+4)
0.01Hz
Capacitance
60n/600n/6μ/60μ/600μ/2000μF
±(2.0%+5)
0.01nF
Continuity
Buzzer sounds at below 10-200Ω Open voltage: approx. 0.5V
Diode test
Open voltage: approx. 1.8V
EF sensing
A voltage or electric field of about 60 V or more is detected. The barr graph and intermittent buzzer beeps change in three steps according to the field intensity. (50/60Hz)
Sampling rate
Approx. 5 times/sec.
Bandwidth
50~400Hz
Display
6000/1999(Hz)
Max. overload protection input
DC/AC1100V
CT: DC/AC2000A
Clamp diameter/Conductor size
Φ55mm/20x66mm
Battery
R6Px2
Battery life
A function: Approx. 80 hrs. Functions other than A: Approx. 240 hrs. (Zinc-carbon battery/Backlight off)
Size/Mass
H264×W97×D43mm/Approx. 640g
Safety standards
IEC61010 CAT Ⅳ 1000V
0 Reviews Write a review
Categories: Clamp meters
DCM301 | AC Clamp Meter with Multimeter Functionality
Specifications
Function
Measuring Range
Accuracy
Resolution
ACA
60.00/600.0/1000A
±(2.5%+5)
0.01A
ACV
6.000/60.00/600.0/1000V
±(1.5%+3)
0.001V
DCV
6.000/60.00/600.0/1000V
±(1%+3)
0.001V
Resistance
6.000k/60.00k/600.0k/6.000M/60.00MΩ
±(2%+5)
0.001kΩ
Frequency
ACV 10Hz-10kHz, ACA 10Hz-2kHz
±(1%+5)
0.1Hz
Capacitance
60.00n/600.0n/6.000µ/60.00µ/600.0µ/6.000m/60.00mF
±(4%+3)
0.01nF
Continuity
Buzzer sounds below 30Ω Open voltage: approx. 1V or less
Detection of Electricity
Buzzer sounds, "-" is shown on LCD, and LED flickers
Detects ACV and EF of approx. 90V or more (50/60Hz)
Sampling rate
Approx. 3 times/sec.
Bandwidth
ACA 45-400Hz ACV 45Hz-1kHz
Display
6000/9999(Hz function)
Clamp diameter/Conductor size
Φ34mm/10×64mm
Battery
LR03×3
Battery life
Approx. 200 hrs.
Size/Mass
H252×W85×D40mm/Approx. 360g
Safety standards
IEC61010 CAT.Ⅳ600V/CAT.Ⅲ1000V
0 Reviews Write a review
Categories: Clamp meters
DCM400 | Basic Digital Clamp Meter with Multimeter Functionality
Specifications
Function
Range
Accuracy
Resistance
ACA
40/400A
±(1.9%+5)
0.01A
ACV
400/600V
±(1.5%+5)
0.1V
DCV
400/600V
±(1%+2)
0.1V
Resistance
400Ω
±(1%+2)
0.1Ω
Frequency (A)
20~4k/10kHz
±(0.1%+1)
1Hz
Frequency (V)
4k/40k/400k/1MHz
±(0.1%+1)
0.001kHz
Continuity
Buzzer sounds at less than approx. 40Ω
Open voltage: approx. 1.5V
Sampling rate
2 times/sec., 20 times/sec. for bar graph
Bandwidth
ACA 50/60Hz: ±(1.9%+5) 60-500Hz: ±(2.5%+5)
ACV 50-500Hz: ±(1.5%+5)
Display
4000
Clamp diameter/Conductor size
Φ25mm/10×34mm
Battery
R03×2
Battery life
Approx. 150 hrs. (Zinc-carbon battery)
Size/Mass
H193×W50×D28mm/Approx. 230g
Safety standards
IEC61010 CAT.Ⅲ300V CAT.Ⅱ600V
0 Reviews Write a review
Categories: Clamp meters
DCM400AD | Clamp Meter for Automotive Maintenance & Digital Multimeter Functions
SPECIFICATIONS
Function
Range
Accuracy
Resolution
ACA
40/400A
±(2%±10)
0.01A
DCA
40/400A
±(2.5%±10)
0.01A
ACV
400/600V
±(1.5%±5)
0.1V
DCV
400/600V
±(1%±2)
0.1V
Resistance
400Ω
±(1%±2)
0.1Ω
Continuity
Buzzer sounds at less than approx. 40Ω
Open voltage: approx. 1.5V
Sampling rate
2 times/sec., 20 times/sec. for bar graph
Bandwidth
50~500Hz
Display
4000
Clamp diameter/Conductor size
Φ25mm/10×34mm
Battery
LR03×2
Battery life
Approx. 50 hrs.(Alkaline battery)
Size/Mass
H193×W50×D28mm/Approx. 230g
Safety standards
IEC 61010 CAT.Ⅲ 300V CAT.Ⅱ 600V
0 Reviews Write a review
Categories: Clamp meters
DCM600DR | Clamp Meter for Automotive Hybrid / Electric Vehicle + DMM Functionality
Specifications
Function
Range
Accuracy
Resolution
Input Impedance
DCA
60/600A
±(2%+5)
0.01A
ACA
60/600A
±(2%+5)
0.01A
DCV
600V
±(1%+2)
0.1V
1MΩ
ACV
600V
±(1.2%+5)
0.1V
Resistance
999.9Ω
±(1%+7)
0.1Ω
Continuity
Buzzer sounds at less than 40Ω
Open voltage: Approx. 2.9V
Sampling rate
3 times/sec.
Bandwidth
50-500Hz
Display
6000
Clamp diameter/Conductor size
Φ30mm/10×50mm
Battery
LR03×2
Battery life
Approx. 40 hrs. (Backlight off)
Size/Mass
H208×W69×D38mm
Approx. 260g
Safety standards
IEC61010 CAT.Ⅲ600V
*In the peak hold mode, the measuring range is fixed at 600A.
0 Reviews Write a review
Categories: Clamp meters
DCM60R | Digital Clamp Meter / Multimeter
Specifications
Function
Range
Accuracy
Resistance
ACA
199.9/600A
±(2%+5)
0.1A
ACV
199.9/600V
±(1.5%+5)
0.1V
Resistance
199.9Ω
±(1.0%+8)
0.1Ω
Continuity
Buzzer sounds at less than 100Ω
Operation method
Δ-Σ method
AC measuring method
True RMS
Sampling rate
2 times / sec
Display
1999 count
Range selection
Auto
Battery low warning
Battery ( ) mark lights at approx. 2.2V or below
Operating temperature / humidity
0℃~40℃, below 80%RH No condensation
Storage temperature / humidity
-10℃~60℃, below 70%RH No condensation
Continuous use time
About 250 hours
Power consumption
Approx. 5.0mW
Safety standards
IEC61010-1, IEC61010-2-030 CAT.III 300V / II 600V
IEC61010-2-032, IEC61010-2-033, IEC61010-31
Bandwidth
50~400Hz
Clamp diameter / Conductor size
25mm / 10 x 30mm
Battery
R03(UM-4) or AAA x 2
Size / Mass
H187 x W50 x D29mm / 210g
Standard accessories included
Test leads (TL-21a), carrying case (C-DCM60L), instruction manual
0 Reviews Write a review
Categories: Clamp meters
DCM660R | True RMS Clamp Meter for Electrical and HVAC Work + DMM Functions
Specifications
Function
Measuring Range
Accuracy
Resolution
Input Impedance
ACA
66/660A
±(2%+5)
0.01A
DCV
600V
±(1%+2)
0.1V
1MΩ
ACV
600V
±(1.2%+5)
0.1V
Frequency (A)
660/6.6k/30k
±(0.2%+1)
0.1Hz
Frequency (V)
660/6.6k/66k/100k
±(0.2%+1)
0.1Hz
Resistance
660Ω
±(1%+7)
0.1Ω
Continuity
Buzzer sounds at less than 30Ω Open voltage: approx. 1.2V
Sampling rate
3 times/sec.
Bandwidth
50-500Hz
Display
6600
Clamp diameter/Conductor size
Φ30mm/10×50mm
Battery
LR03×2
Battery life
Approx. 55 hrs.(Alkaline battery/Backlight off)
Size/Mass
H208×W69×D38mm/Approx. 265g
Safety standards
IEC61010 CAT.Ⅲ600V
0 Reviews Write a review
Categories: Insulation resistance testers
DM1009S | 1000V Analog Insulation Tester / Portable Insulation Resistance Meter
Specifications
Scale(MΩ)
1~2~1000~2000MΩ
Tolerance
± 5% of reading(1st effective measurement range: written in the thick print above)
±10% of reading(2nd effective measurement range: written in small type above)
ACV
600V
Tolerance
Within ±5% of the max. scale value(50~60Hz sine wave)
DCV
60V
Tolerance
Within ±5% of the max. scale value
Rated current
1.0~1.2mA
Battery
6LF22/6LR61 (9V alkaline battery) x1
Size/Mass
H144×W99×D43mm / Approx. 310g
Safety standard
IEC61010 CAT.Ⅲ 600V
0 Reviews Write a review
Categories: Insulation resistance testers
DM509S | 500V Analog Insulation Tester / Portable Insulation Resistance Meter
Specifications
Measuring Range
Accuracy
MΩ (Insulation Resistance)
500V/1000MΩ
1st effective measurement range: ±5% of full scale 2nd effective measurement range: ±10% of a full scale
DCV
60V
±5% of full scale
ACV
600V
±5% of full scale
Rated measuring current
1~1.2mA
Meter type
Internal magnet, Taut-band meter(24μA)
AC rectifier form
Half-wave rectification (Mean value indication rms value converted)
Operating temperature / humidity
0℃~43℃ 80%RH or below No condensation
Storage temperature / humidity
-10℃~50℃ 70%RH or below No condensation
Operating environment
Altitude 2000m or less, environmental pollution degree II
Power consumption
Approx. 2.0W~2.8W(At 500V/100MΩ range)
Battery consumption
Checked by BATTERY CHECK range
IP rate
IP20
EN61010-1 CAT.II EN61010-1 CAT.III
1000V 600V
Battery
6LR61 (9V) x 1
Size / Mass
H144 x W99 x D43mm / 310g
Standard accessories included
Test lead (TL-509S), Carrying case (C-09S), Instruction manual
0 Reviews Write a review
Categories: Detectors
KS1 | 3 Phase Detector - Contact Type
Specifications
Measurement
Open Phase and Phase Rotation Detection
Voltage range
3 Phase AC100 to 500 V
Frequency
45 to 70 Hz
Time limit
AC110V: Continuous
AC220V: 3 hours
AC480V: 12 minutes
Safey standards
IEC61010-1 CATⅢ 500V
IEC61326、IEC61010-031
Size/Mass
102(H)×78(W)×32.5(D)mm / approx. 212 grams
Cord length
Approx. 0.6 m
Accessories
Carrying pouch, instruction manual x 1
0 Reviews Write a review
Fashion online store is very important in this time if you are trying to sell clothes. With the new fashion trends and all the available shopping options you can order your clothes online and make money without even leaving your house. These days you can take your own inspiration and create something new for yourself. All you need to do is read books and magazines about fashion, watch videos on youtube, keep yourself updated on social media, and of course also shop online!